Micro Credit Management Software Free Download

Micro Credit Management software, free downloadSoftware

Microsoft Office 2016 16.0 can be downloaded from our website for free. Some users state that the software features the following benefits: it has a nice interface and works well. The software relates to Office Tools. Our built-in antivirus checked this download and rated it as virus free. The actual developer of the software is Microsoft. This software is available to the community of micro finance institutions. OCTOPUS MFS is an integrated suite allowing full management of a Micro Finance Institution: client management, accounting. Why need Micro credit Software Solutions Services? Micro Credit is the provision of financial services that target low-income clients, particularly women and people living in poverty In Bangladesh. In simple word we can say Micro Credit means building financial systems that serve the poor. Micro Credit Software is basically use.

  • This tool guide focuses on credit scores – a number that represents an assessment of the creditworthiness of a person, or the likelihood that the person will repay a loan. Financial institutions use scoring models to assess the credit risk of a borrower and aid in the credit evaluation processes.
  • It can be customized to any workflow and can integrate Credit Bureau or Anti Money Laundering blacklists checks. The system allows document upload and task management with alerts. The system is integrated with OpenCBS but can also be interfaced with other Core Banking Systems.
Download

μManager™ is a trademark of The Regents of the University of California. Used with Permission.

Micro-Manager versions

Currently, there are 2 usable versions of Micro-Manager: 1.4 and 2.0-gamma. These versions use the same code to interface to devices, but differ in their user interface, and file reading/saving code. 2.0-gamma is actively developed and maintained. 1.4 is no longer developed (except for the device support and the ASI diSPIM plugin). If you start using Micro-Manager, it is recommended to use the latest nightly build of 2.0-gamma.

Due to security issues on OSX 10.12 and later, Micro-Manager does not start when opening ImageJ. To circumvent this, within the Micro-Manager folder in Applications, hold command and drag ImageJ onto the desktop. Then hold command and drag it back in. Then try running again. See Installation Notes.

Nightly Builds

Although there has been no official release for quite some time, further development and multiple bug fixes have occurred in the 1.4 branch in parallel with development of 2.0. Nightly builds are almost always stable and a better choice for most users than the latest official release.

  • Version 2.0-gamma (Windows) (you most likely want the 64-bit version)
  • Version 1.4 (Windows) (pay attention to 32-bit or 64-bit, both are listed but you need the one matching your Windows OS)

Micro-Manager 1.4.22 (August 14, 2015)

Free Micro Software Downloads

Read the Known Issues.

  • Windows 32-bit, 63.4 MB
  • Windows 64-bit, 65.1 MB

Requires Windows XP, or 7-10. Windows 7 recommended. Device drivers may have other requirements.

  • Mac OS X (Universal Binary), 54.0 MB

Micro Credit Management software, free download For Windows 7

Requires Mac OS X 10.5-10.10. 10.11 (El Capitan) is not yet supported. Device drivers may have other requirements.
(OS X 10.8 and later: if the application does not open when double-clicked for the first time, try ctrl-click or right click, then select 'Open'.)

  • Under GNU/Linux platforms, you should compile micro-manager from source.

Known issues in 1.4.22

  • If you use AndorSDK3 (Andor sCMOS cameras) and experience a crash upon starting Micro-Manager (or loading a hardware configuration), please upgrade to the 20150820 nightly build (Windows 64-bit, Windows 32-bit)
  • Olympus IX83 users: please use 1.4.21 instead.

Changes in 1.4.22 (since 1.4.21)

Micro Credit Management software, free download
  • Bugfixes and enhancements in the main application
    • Fix a hang when restarting MDA with data processors installed while Live mode is running (Mark Tsuchida)
    • When adding Z stage devices, the user may now specify the directionality of the stage (whether positive or negative directions move closer to the sample)
    • Fix a bug with storage of user configuration data on Windows 8 and later operating systems (Chris Weisiger)
    • Bugfixes relating to saved data:
      • Fix a minor bug in formatting of metadata in multipage TIFF files (Mark Tsuchida)
      • Fix a bug causing truncation of OME Medatada (Chris Weisiger)
      • Fix a memory leak noticeable when running acquisitions with large position lists (Chris Weisiger)
    • Display bugfixes:
      • Fix a bug causing RGB channels to be swapped when loading files (Chris Weisiger)
      • Fix display of total timepoints in cancelled acquisitions (Chris Weisiger)
    • Fix a bug in behavior of slider controls in European locales (Mark Tsuchida)
    • Fix a NullPointerException when the logfile directory is missing (Mark Tsuchida)
    • Fix a NullPointerException in the Metadata panel (Nico Stuurman)
    • Correctly remember autofocus parameters in preferences (Mark Tsuchida)
    • Enable high-resolution rendering on Macs with Retina Displays
    • Add setting for focus stage coordinate polarity in Hardware Configuration Wizard (Mark Tsuchida)
  • New plugins
    • Mightex Polygon, for controlling the Polygon patterned illuminator devices
  • Updated plugins
    • ASIdiSPIM: numerous bugfixes and improvements (Jon Daniels, Nico Stuurman)
    • Projector: numerous bugfixes and improvements (Jon Daniels, Nico Stuurman)
    • HCS Site Generator
      • Improved acquisition pathing within a well, using a snakelike route (Nico Stuurman)
      • add support for 6- and 12-well plates (Thomas Petebauer, Chris Weisiger)
  • Autofocus plugins
    • Added NullAutofocus, an autofocus method that does nothing, useful in certain complex acquisitions (Mark Tsuchida)
  • New device adapters
    • CNCMicroscope adapters (David Konerding)
      • ArduinoNeoPixel: Adafruit NeoPixel sheild as a shutter
      • RAMPS: RepRap RAMPS/Marlin motor drivers as XY and Z stage
    • Diskovery: Andor Diskovery multi-modal imaging system (Nico Stuurman)
    • Standa8SMC4: An alternative Standa stage adapter using the XIMC motion control library (Eugene Seliverstov)
  • Updated device adapters
    • Andor: Update Andor DLLs; add iXon 888 isolated crop ROIs; support FVB mode; add hardware timestamps on compatible cameras; fix Exposure display (Matthew Milford, Andor)
    • AndorSDK3: Allow fast exposure switching for Snap; allow switching on/off static blemish correction; add shutter control properties (Matthew Milford and Francis McCloy, Andor)
    • AndorShamrock: Add Rayleigh wavelength property; other fixes (Francis McCloy, Andor)
    • ASITiger: Support SetOriginX/Y; updates to scanner and PLogic; hardware sequencing support for piezo (Jon Daniels, ASI)
    • Cobolt: Fix a serial communication issue (Mark Tsuchida)
    • GigECamera: Avoid an error while connecting with some cameras (Mark Tsuchida)
    • IIDC: Add limited/experimental color camera support (Mark Tsuchida)
    • LeicaDMI: Add fixed shutter delay setting (Egor Zindy); fix turret control issues with DMi8 (Mark Tsuchida)
    • Marzhauser: Fix potential serial communication issue (Falk Dettmar, Marzhauser)
    • Mightex_C_Cam: Updates (JT Zheng, Mightex)
    • NI100X (National Instruments): Add support for hardware-triggered sequencing (Chris Weisiger)
    • OpenCVgrabber: update from OpenCV 2.4.8 to 2.4.9 on OS X (Mark Tsuchida)
    • PCO_Camera: Fix issue when using software trigger mode with pco.camera (Franz Reitner, PCO)
    • PI: Fix serial connection issue with certain controllers (Mark Tsuchida)
    • PICAM: Allow use of multiple cameras (Mark Tsuchida)
    • PVCAM: Fix a crash when enabling Color during Live; fix a possible Snap failure after changing binning and ROI; prevent timeout with slow cameras (Photometrics)
    • Prior: Fix a communication issue with certain controllers (Mark Tsuchida)
    • Sapphire: Fix a serial communication issue (Mark Tsuchida)
    • SpectralLMM5: Add FLICR (PWM) and fiber output selection support (Nico Stuurman)
    • StandaStage: Disable limit switch setting causing issues with some setups (Ed Simmons)
    • SutterLambda: Add setting for filter wheel timeout (Nico Stuurman)
    • XIMEA: Fix crash upon Snap; use camera timestamp resetting only for applicable cameras; add missing GPO port modes for MU USB2 (Marian Zajko, XIMEA)
    • Yokogawa CSU22, CSUX, CSUW1: Fix a possible hang; speed no longer a state device (Pariksheet Nanda)
    • ZeissCAN: Fix problem while disconnecting when connected by USB (Nico Stuurman)
  • New closed-source device adapters
    • MightexPolygon: Mightex Polygon multiwavelength patterned illuminators (Mightex)
  • Updated closed-source device adapters
    • HamamatsuHam: Fix ROI coordinates when binning enabled (Nico Stuurman)
    • Olympus: Fix Focus Sensitivity setting (Mark Tsuchida)
    • OlympusIX83: Prevent reporting incorrect stage position immediately after move (Mark Tsuchida)
    • RaptorEPIX: Add support for OWL640, Ninox and Eagle cameras (David Biggs)
  • Changes of interest to developers
    • Micro-Manager 1.4.22 is SVN trunk r15693, 3rdparty r176.
    • All but a few of the Java dependency JARs are now fetched from Maven repositories using Ivy, rather than using the copy in 3rdpartypublic/classext (Mark Tsuchida)
    • Add an unregisterForEvents() method to the gui (ScriptInterface) API (Henry Pinkard)
    • MMCore API changes
      • Add methods setOriginX(), setOriginY() for XY stages that allow zeroing X and Y independently (Mark Tsuchida)
      • The home() and stop() method now also work with Z/focus stages (where supported) (Mark Tsuchida)
      • Add methods setFocusDirection(), getFocusDirection(), allowing to store and retrieve focus stage coorinate polarity where known. Explicitly set values are recorded in hardware configuration file (Mark Tsuchida)
      • Add methods getGalvoXMinimum(), getGalvoYMinimum() (Nico Stuurman)
    • MMDevice interface changes
      • Add optional methods to set X and Y origin separately for XY stages (SetXOrigin() and SetYOrigin()) (Mark Tsuchida)
      • Add optional Home() and Stop() methods to Z/focus stages (Mark Tsuchida)
      • Add optional GetFocusDirection() to Z/focus stages (Mark Tsuchida)
      • Add GetXMinimum(), GetYMinimum() methods to galvo device (Nico Stuurman)
      • The HubID property is now read-only (Nico Stuurman)
  • Miscellaneous
    • Added a MATLAB script, StartMMStudio.m that configures and starts MMStudio (Windows only) (Mark Tsuchida)


(Previous releases)

Credit
Retrieved from 'https://micro-manager.org/w/index.php?title=Download_Micro-Manager_Latest_Release&oldid=11768'